A backup generator is the bridge in an off-grid system, not the foundation. Solar, wind, or a stream do the daily work; batteries carry the night. The generator covers the gaps: a cloudy week, a calm spell, a bank that needs charging. Too small, it shuts down when you need it most. Too large, it costs more and burns more fuel for no benefit. Here is how to size one from your own loads, how the fuels compare, and the voltage check US buyers must do first.

Check voltage, frequency, and phase first

Most US homes run on 120/240-volt split-phase power at 60 Hz. Many listings are built for other markets: 220- or 230-volt output, sometimes 400-volt three-phase, at 50 Hz. The wrong voltage or frequency can damage appliances, whatever the wattage. Check the listing and datasheet first for voltage, frequency, phase, and receptacle types. Several generators in our store are listed at 220, 230, or 220/380 volts and 50 Hz, and say so plainly. Do not assume such a unit fits US household power, and confirm the exact variant: one model name can cover single- and three-phase versions.

Never plug a portable generator directly into household wiring, and never let it backfeed into the grid or a solar system. Use a transfer switch or interlock installed by a licensed electrician, or extension cords to individual appliances. If you plan to charge a battery bank, confirm your inverter or charger accepts the generator's output. See our inverters and LiFePO4 batteries.

Size from running watts plus starting surge

Every load has two numbers: running watts, and starting watts, the brief surge a motor draws at startup. Refrigerators, freezers, well pumps, and tools all surge. Your generator must handle the running watts of everything running at once, plus the largest motor's starting surge. List your loads, read both numbers from each nameplate, add the running watts, then add the largest surge. That is your minimum continuous output. Leave headroom: a generator running flat out has nothing left for the next surge.

Illustration only, with round numbers: 2,000 watts running plus a 1,500-watt starting surge needs at least 3,500 watts continuous when that motor starts, plus headroom. Your numbers will differ; only your nameplates count. Watch peak versus rated watts: peak lasts seconds, rated is what the machine sustains. Several listings in our store advertise peak while stating rated output is not clearly established. Verify the rated figure in the datasheet first.

Gasoline, propane, or diesel?

Gasoline is the easiest fuel to find, and most small portables run on it. Its weakness is storage: gasoline goes stale, especially ethanol-blended fuel, so stored fuel needs stabilizer and rotation. It suits short outages with easy refueling, and long storage poorly.

Propane (LPG) does not go stale in a sealed tank, so a full cylinder can wait months and still be ready. The trade-offs: a gallon of propane generally holds less energy than gasoline, so expect shorter runtime, and output is often slightly lower on propane. Check the manual's runtime and rating per fuel.

Diesel suits larger, longer-running backup, and stores well when kept clean and dry. The trade-offs are weight, cost, and cold weather, since diesel can gel without winter treatment. Dual-fuel models (usually gasoline and propane) add flexibility, but carry two sets of numbers to verify, one per fuel.

Size classes in our store

These examples show how the classes differ; none promises a given unit will run your loads. Each rating comes from the listing, and each listing says to confirm the configuration and datasheet first.

Small inverter, about 3,000 watts peak. The quiet inverter generator advertised at 2,900 watts peak suits campsites, RV use, and a handful of essentials. Its listing states rated output was not confirmed, so verify it before sizing it for a motor load.

Mid-size dual-fuel, 4,000 to 4,650 watts peak. The quiet dual-fuel inverter generator advertised at 4,200 watts peak and the VEVOR dual-fuel generator (4,650 peak on gasoline, 4,130 on LPG) both state rated output is not clearly specified. Only the rated output on your fuel decides what runs.

Five to eight kilowatts, gasoline. The GEEMKA KH8000 is listed at 5 kW rated, 5.5 kW maximum (single-phase), 389 cc, 15-liter tank, at 50 Hz and 230 or 400 volts: US buyers must confirm voltage, frequency, and phase. The KATOMAX CP10000 (8 kW class, 389 cc, 25-liter tank) is listed at 220 volts, 50/60 Hz, single- or three-phase.

Large dual-fuel: verify before trusting the headline. The portable dual-fuel generator advertises 13,500 watts peak on gasoline and 12,000 on LPG, while the same listing also references a 4 kW maximum rating. When ratings disagree, the datasheet is the only tiebreaker.

Diesel, six to nine kilowatts. The KATOMAX portable diesel generator covers 6 to 7 kW, 12.5-liter tank, 220/380 volts at 50 Hz. The GEEMKA diesel set is labeled 9 kW / 11 kVA, open-frame or extended-silent, 110 to 400 volts. Confirm the exact rating, voltage, and enclosure. See our generators page.

How a generator fits the whole system

In a full off-grid setup, the generator is rarely the main source: solar and wind charge the batteries, and the inverter carries the house. The generator steps in when renewable input falls short. Size it to your charger and largest simultaneous load, not the whole house at once. See our guide to whether a portable power station can run a house and our micro-hydro guide. For short outages, a portable power station may be simpler, with no fuel.

Safety, plainly

Run a generator outdoors only, far from doors, windows, and vents, never in a garage, even with the door open. Exhaust contains carbon monoxide, which is colorless and odorless. Install carbon monoxide detectors and let the engine cool before refueling. Follow the manual for oil and exercise runs: a generator that sits for a year may not start, and stale fuel is the usual reason. Unsure about wiring? Hire a licensed electrician.

Frequently asked questions

What size generator do I need?

Add the running watts of everything running at once, plus the largest motor's starting surge and headroom. Essentials and whole-house lists give different answers.

Peak watts or rated watts?

Rated watts: peak covers seconds, rated is what the machine sustains. If only peak is advertised, confirm rated in the datasheet.

Gasoline, propane, or diesel?

Gasoline is easiest to find, propane stores longest, diesel suits longer-running backup. Dual-fuel adds flexibility, with a rating per fuel to verify.

Can a generator charge my battery bank?

Yes, if voltage, frequency, and output match your inverter or charger. Confirm in the manuals first.

Can I use a 220-volt or 50 Hz generator in a US home?

Not without confirming compatibility: US power is 120/240 volts at 60 Hz. Check the datasheet, variant, and your electrician's advice.

Start with your load list, not a listing page. Add the watts, add the surge, check voltage and frequency, and verify the datasheet. For help checking a unit against your loads, contact us with your load list, voltage, and fuel preference. Nova Bliss, Ocean Springs, Mississippi. Call +1 228-696-3541. Free shipping, delivery in 1–2 weeks, returns within 30 days.